Boilers with feeder biomass

Smart EkoPell

gwarancja_5_lat 5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;
stal Heat exchanger made of certified high-grade boiler steel;
sprawnosc_90 High thermal efficiency reaching 90% due to increased heat recovery from flue gases;
sterownik_APC_3 APC 3 ADAPTIVE CONTROL 3 servicing six pumps /central heating, domestic hot water, circulating, floor/. Control of two mixing valves; preview and change of parameters of the main controller ONLINE through built-in internet module with RJ-45 connector;
NZ Reinforced design. Boiler adapted for installation in closed system if the protections are assembled in accordance with the operation and maintenance manual of the boiler;
palnik_pelletowy_centralny
Central pellet burner with automatic cleaning function as a standard;
adaptive_control
ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger;
ceramika Ceramic catalysts stabilising combustion process;
automatyczny_zaplon Fuel self-ignition system;
wentylator_wyciagowy Exhaust fan eliminating problem with chimney draught and stabilising operation of the boiler;
TTS
Twin Spark System- pellet burner equipped with two igniters as a standard - option available for all powers;
czujnik_rezerwy_paliwa
Fuel reserve sensor in container stops boiler operation at minimum fuel level. After fuel recharging it is not necessary to repeat firing procedure and the boiler switches to automatic operation;
Specification / boiler type unit 12 16 20 24 28 38

Fuel

- wood pellet with diameter 6-8 mm

Power range

kW 3,6-12 4,8-16 6,0-20 7,2-24 8,4-28 11,4-38

Heating area

m2

1,6 1,8 2,2 2,6 3,2 3,6

Area of heated rooms 1

m2

to 150 to 200 to 250 to 300 to 350 to 475

Capacity of fuel
container 2

kg ~195 ~195 ~195 ~195 ~195 ~195

Optimum thermal efficiency

% ~88,3-90,1

Energy efficiency class

- A+ A+ A+ A+ A+ A+

Max. permissible work pressure

bar 1.5

Required flue gas draught

Pa 20 22 24 26 28 29
Water temperature on supply max. °C 65/85

Boiler weight 3

kg 374 396 424 451 493 528

Boiler water tank capacity

l 51 57 64 73 86 98

Chimney section

cmxcm 14x14 14x14 14x14 15x15 16x16 18x18

Chimney section

Ø mm

160 160 160 170 180 200

Minimum chimney height

m

6

6,5

7

7,5

8

9

Supply and return socket diameter

mm

G1 ½”

Diameter of the exhaust gas socket

mm 127 127 127 127 127 127

Supply

V/Hz

~230/50

1 Maximum area of heated rooms estimated for unit heat demand q=80 W/m2.

2 Fuel tank capacity for pellet bulk density 0,6 kg/dm3.

3 Boiler weight depends on its additional equipment.

 

Height of boiler can be additionally adjusted by means of provided levelling legs.

The regulation of legs varies from 38 to 50 mm.