Boilers with feeder biomass

Beta

Zobacz produkt w 360°

gwarancja_5_lat.jpg 5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;
stal.jpg Heat exchanger made of certified high-grade steel;
sprawnosc beta High thermal efficiency in the range from 91,7 to 95,3% due to increased heat recovery from flue gases;
sterownik_APC_Center.jpg APC CENTER servicing six pumps /central heating, domestic hot water, circulating, floor/. Control of two mixing valves; preview and change of parameters of the main
controller ONLINE through built-in internet module
with RJ-45 connector;
NZ.jpg Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler;
piktogram_automatyczne_czyszczenie.jpg Mechanical heat exchanger cleaning system;
czujnik podcisnienia Vacuum sensor protecting against incorrect combustion process;
ceramika.jpg Ceramic catalysts stabilising combustion process;
uklad_samoczynnego_zaplonu.jpg Central pellet burner with automatic cleaning function as a standard;
palnik_pelletowy_centralny.jpg Centralny palnik pelletowy z funkcją automatycznego czyszczenia w standardzie;
lambda.jpg Lambda probe - Smart algorithm optimizing the combustion process and ensuring the highest efficiency of the boiler with minimum emission of flue gas for the full range of powers;
 wentylator_wyciagowy.jpg
Exhaust fan eliminating problem with chimney draught and stabilising operation of the boiler;
kompaktowe_wymiary.jpg Compact dimensions;
czujnik rezerwy paliwa Fuel reserve sensor in container stops boiler operation at minimum fuel level. After fuel recharging it is not necessary to repeat firing procedure and the boiler switches to automatic operation;
TTS Twin Spark System - pellet burner as standard equipped with two igniters;

Specification / boiler type

unit 12 17 22 26 30 40
Power range kW 3,5-11,8 5,0-16,6 6,5-21,4 7,4-25,1 8,2-28,8 10,4-38,1
Heating area

m2

1,6 1,8 2,1 2,5 2,9 3,3

Area of heated rooms 1

m2

do 150 do 215 do 275 do 325 do 375 do 500

Capacity of fuel container (STD / PLUS ) 2

kg ~77 / ~160 ~77 / ~160 ~104 / ~208 ~135 / ~237 ~135 / ~237 ~153 / ~244
Optimum thermal efficiency % 91,7 95,3 93,9 93,0 93,0 93,8
Energy efficiency class   A+ A+ A+ A+ A+ A+

Max. permissible work pressure

bar 3,0
Required flue gas draught mbar 0,12 0,16 0,20 0,21 0,22 0,25

Water temperature on supply max.

°C 65/80

Boiler weight (STD / PLUS) 3

kg

~301 /
~321

~317 /
~337

~344 /
~366

~389 /
~410

~433 /
~454

~486 /
~503

Boiler water tank capacity l 53 54 64 71 85 92
Chimney section cmxcm 14x14 14x14 16x16 16x16 18x18 18x18
Chimney section

Ø mm

160 160 180 180 200 200

Minimum chimney height 

m

5

5,5

6

6,5

7

7,5

Supply and return socket diameter

cal

1’’ 

Release socket diameter

cal

½ ’’

Diameter of the exhaust gas socket

mm 130
130 130 130 130 127

 

1 Maximum area of heated rooms estimated for unit heat demand q=80 W/m2.

2 Fuel tank capacity for pellet bulk density 0,6 kg/dm3.

3 Boiler weight depends on its additional equipment.

 

Height of boiler can be additionally adjusted by means of provided levelling legs. The regulation of legs varies from 38 to 50 mm.