Boilers with feeder for coal

Komfort Eko Mini

Zobacz produkt w 360°



gwarancja_5_lat 5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;
stal_6mm Heat exchanger made of certified high-grade steel;
sprawnosc_90 High thermal efficiency reaching 92% due to increased heat recovery from flue gases;
sterownik_K1P4.jpg Controller K1P4 with colour touch panel servicing four pumps /central heating, domestic hot water, circulation, floor pump/. Servicing of mixing valve. Possibility to control using GSM or INTERNET - extra paid option; adjustable position angle of the control panel;
NZ
Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler;
bar Pressure equalisation system in fuel container;
czopuch Vertical or horizontal configuration of the flue after the installation of the torsion bend (the torsional bend does not constitute the boiler’s equipment);
ceramika Ceramic catalysts stabilising combustion process;
palnik_retortowy Combustion chamber with highly effective retort burner;
drzwiczki Changing the direction of door opening
(does not apply to the inner door);
piktogram_zasobnik_lewy_prawy.jpg
Possibility of moving the fuel tank;
slimak Feeder screw made of one element;

Specification / boiler type

unit 11 15 20 24 40

Power range

kW 3,5-11 4,4-15 5,8-20 6,9-24 12,3-40

Heating area

m2

1,4 1,6 1,9 2,7 3,9

Area of heated rooms 1

m2

to 150 to 190 to 250 to 315 to 500

Capacity of fuel container 2

kg ~132 ~132 ~132 ~191 ~258

Optimum thermal efficiency

% ~90-92,9

Energy efficiency class

  C C B C C

Max. permissible work pressure

bar 1,5

Required flue gas draught

mbar 0,21 0,25 0,16 0,30 0,34
Water temperature on supply max. °C 65/80

Boiler weight 3

kg 385 411 449 546 729

Boiler water tank capacity

l 60 68 78 104 144

Chimney section

cmxcm 14x14 14x14 14x14 16x16 22x22

Chimney section

Ø mm

160 160 160 180 245

Minimum chimney height

m

5,5

6

6

7

7

Supply and return socket diameter

cal

1 ½ ’’ 

Release socket diameter

cal

½ ’’

Diameter of the exhaust gas socket

mm 159 159 159 178 178

 

1 Maximum area of heated rooms estimated for unit heat demand q=80 W/m2.

2 Fuel tank capacity for bulk density of eco-pea coal equal to 0,8 kg/dm3.

3 Boiler weight depends on its additional equipment.

 

Height of boiler can be additionally adjusted by means of provided levelling legs.

The regulation of legs varies from 38 to 50 mm.

Visitors counter: 6533111 , today: 31 , yesterday: 52 , online: 0