Boilers with feeder biomass

Eko Slim

Zobacz produkt w 360°
gwarancja_5_lat.jpg 5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;
stal.jpg Heat exchanger made of certified high-grade steel;
sprawnosc eko slim High thermal efficiency in the range from 90,2 to 93,1% due to increased heat recovery from flue gases;
sterownik_APC_K_slim.jpg APC K SLIM ADAPTIVE CONTROL servicing four pumps /central heating, domestic hot water, floor/. Control of one mixing valve; preview and change of parameters of the main ONLINE controller - extra payable option;
NZ Reinforced design. Boiler adapted for installation in closed system if the protections are assembled in accordance with the operation and maintenance manual of the boiler;
adaptive_control ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger;
ceramika Ceramic catalysts stabilising combustion process;
automatyczny_zaplon Fuel self-ignition system;
 palnik_pelletowy_centralny Pellet burner with automatic cleaning function in standard;
kompaktowe_wymiary
Compact dimensions;

technical data of the boiler / PRODUCT GROUP D

Specification / boiler type

unit 10 15 20 25 30

Fuel

- wood pellet with diameter 6 mm

Power range

kW 2,9-10,5 4,3-14,8 5,8-20,7 7,3-25,1 8,8-31,6

Heating area

m2

1,5 2,1 2,5 2,7 3,3

Area of heated rooms 1

m2

to 160 to 220 to 270 to 355 to 425

Capacity of fuel container 2

kg ~102 ~122 ~126 ~126 ~147
Nominal thermal efficiency % 91,8 91,8 91,4 91,7 91,8
Minimum thermal efficiency % 91,5 92,3 92,7 92,1 92,5

Energy efficiency class

- A+ A+ A+ A+ A+

Max. permissible work pressure

bar 1,5 opened sytem; 3,0 closed system

Required flue gas draught

mbar 0,19 0,21 0,25 0,27 0,29
Water temperature on supply max. °C 65/80

Boiler weight 3

kg 288 336 380 368 402

Boiler water tank capacity

l 48 69 109 97 110

Chimney section

cmxcm 14x14 14x14 14x14 16x16 18x18

Chimney section

Ø mm

160 160 160 180 200

Minimum chimney height

m

5

6

7

7

7

Supply and return socket diameter

cal

GZ 1 ¼’’ / GW 1 ¼’’

Diameter of the exhaust gas socket

mm 127 159 159 159 159

Supply

V/Hz

~230/50

 

1 Maximum area of heated rooms estimated for unit heat demand q=70 W/m2.

2 Fuel tank capacity for pellet bulk density 0,65 kg/dm3.

3 Boiler weight depends on its additional equipment.

 

Height of boiler can be additionally adjusted by means of provided levelling legs.

The regulation of legs varies from 38 to 50 mm.

 

Additional equipment components shall be added during ordering of the boiler because there is no
possibility of installation in the future.

Visitors counter: 6744768 , today: 43 , yesterday: 31 , online: 0