Boilers with feeder biomass
Spectra
DESCRIPTION
![]() |
5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler; |
![]() |
Heat exchanger made of certified high-grade boiler steel; |
![]() |
High thermal efficiency reaching 90% due to increased heat recovery from flue gases; |
![]() |
APC K SLIM ADAPTIVE CONTROL controller servicing three pumps /central heating, domestic hot water, floor/. Control of one mixing valve; preview and change of parameters of the main ONLINE controller - extra payable option; |
![]() |
Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler. |
![]() |
ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger; |
![]() |
Ceramic catalysts stabilising combustion process; |
![]() |
Fuel self-ignition system; |
![]() |
Pellet burner with automatic cleaning function in standard; |
![]() |
Compact dimensions; |
Specification / boiler type |
unit | 10 | 14 | 20 | 25 |
Fuel |
wood pellet with diameter 6 mm | ||||
Power range |
kW | 3,0-10 | 4,2-14 | 6,0-20 | 7,5-25 |
Heating area |
m2 |
1,5 | 1,8 | 2,3 | 3,0 |
Energy efficiency class |
A+ | A+ | A+ | A+ | |
Area of heated rooms 1 |
m2 |
to 125 | to 175 | to 240 | to 300 |
Capacity of fuel container 2 |
kg |
~141 |
~141 |
~152 |
~199 |
Optimum thermal efficiency |
% |
~92,9-94,7 |
|||
Max. permissible work pressure |
bar | 1,5 | |||
Required flue gas draught |
mbar | 0,20 | 0,23 | 0,26 | 0,28 |
Water temperature on supply max. |
°C |
65/80 | |||
Boiler weight 3 |
kg | 340 | 350 | 372 | 467 |
Boiler water tank capacity |
l | 65 | 63 | 71 | 103 |
Chimney section |
cmxcm | 14x14 | 14x14 | 14x14 | 15x15 |
Chimney section |
Ømm |
160 | 160 | 160 | 170 |
Minimum chimney height |
m |
6 |
6,5 |
7 |
7,5 |
Width | mm | 1151 | 1151 | 1201 | 1201 |
Depth |
mm |
835 |
835 |
815 |
960 |
Height |
mm | 1396 | 1396 | 1446 | 1496 |
Supply and return socket diameter |
|
GW 1 ½” |
|||
Release socket diameter |
½” |
½” |
½” |
½” |
|
Diameter of the exhaust gas socket |
mm | 159 | 159 | 159 | 159 |
1 Maximum area of heated rooms estimated for unit heat demand q=70 W/m2.
2 Fuel tank capacity for pellet bulk density 0,6 kg/dm3.
3 Boiler weight depends on its additional equipment.
Height of boiler can be additionally adjusted by means of provided levelling legs.
The regulation of legs varies from 38 to 50 mm.