Boilers with feeder for coal
Komfort Eko Lux - CT / CG
DESCRIPTION
![]() |
5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler; |
![]() |
Heat exchanger made of certified high-grade boiler steel; |
![]() |
High thermal efficiency reaching 90% due to increased heat recovery from flue gases; |
![]() |
Controller K1P v4 with colour touch panel servicing four pumps /central heating, domestic hot water, circulation, floor pump/. Servicing of mixing valve. Possibility to control using GSM or INTERNET - extra paid option; adjustable angle of position of control panel; |
![]() |
Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler. |
![]() |
Pressure equalisation system in fuel container; |
![]() |
ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger; |
![]() |
Optional horizontal or vertical outlet of flue gas - CG option; |
![]() |
Ceramic catalysts stabilising combustion process; |
![]() |
Combustion chamber with highly effective retort burner; |
![]() |
Change of direction of boiler door’s opening (not applicable to internal glow doors); |
![]() |
Coil of endless screw in the fuel feeder made of one piece; |
![]() |
Sensor indicating opening container’s cover; |
![]() |
Energy-saving motoreducer with high efficiency with automatic reverse in case of locking of fuel feeder; |
Specification / boiler type |
J.m. | 9 | 12 | 15 | 20 | 25 | 30 | 40 |
Power range |
kW | 2,7-9 | 3,6-12 | 4,5-15 | 6,0-20 | 7,5-25 | 9,0-30 | 12,0-40 |
Heating area |
m2 |
1,5 | 1,7 | 2,0 | 2,4 | 2,8 | 3,2 | 4,0 |
Area of heated rooms 1 |
m2 |
to 115 | to 150 | to 190 | to 250 | to 315 | to 375 | to 500 |
Capacity of fuel container 2 |
kg | ~132 | ~132 | ~132 | ~191 | ~191 | ~191 | ~258 |
Optimum thermal efficiency |
% | 90,5-90,7 | ||||||
Energy efficiency class |
C | B | B | B | B | B | B | |
Max. permissible work pressure |
bar | 1,5 | ||||||
Required flue gas draught |
mbar | 0,19 | 0,22 | 0,24 | 0,26 | 0,28 | 0,23 | 0,32 |
Water temperature on supply max. | °C | 65/80 | ||||||
Boiler weight 3 |
kg | 407 | 407 | 456 | 529 | 568 | 626 | 769 |
Pojemność wodna kotła | l | 64 | 68 | 82 | 97 | 112 | 123 | 153 |
Chimney section |
cmxcm | 14x14 | 14x14 | 14x14 | 16x16 | 16x16 | 17x17 | 19x19 |
Chimney section |
Ø mm |
160 | 160 | 160 | 180 | 180 | 190 | 220 |
Minimum chimney height |
m |
5 |
5,5 |
6 |
6,5 |
7 |
7,5 |
8 |
Width | mm | 1068 | 1068 | 1063 | 1228 | 1228 | 1278 | 1310 |
Depth (CT) |
mm |
891 |
891 |
962 |
1001 |
1062 |
1092 |
1192 |
Depth (CG) |
mm |
739 |
739 |
810 |
849 |
920 |
940 |
1040 |
Height (CG) | mm | 1426 | 1426 | 1477 | 1528 | 1573 | 1573 | 1583 |
Supply and return socket diameter |
cal |
1 ½ ’’ |
||||||
Release socket diameter |
cal |
½ ’’ |
||||||
Diameter of the exhaust gas socket |
mm | 159 | 159 | 159 | 178 | 178 | 178 | 194 |
1 Maximum area of heated rooms estimated for unit heat demand q=70 W/m2.
2 Fuel tank capacity for bulk density of eco-pea coal equal to 0,8 kg/dm3.
3 Boiler weight depends on its additional equipment.
Height of boiler can be additionally adjusted by means of provided levelling legs.
The regulation of legs varies from 38 to 50 mm.