Boilers with feeder biomass

Gamma

Zobacz produkt w 360°
gwarancja_5_lat.jpg

5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;

stal.jpg Heat exchanger made of certified high-grade steel;
sprawnosc gamma High thermal efficiency in the range from 91,7 to 94,2% due to increased heat recovery from flue gases;
  APC K SLIM ADAPTIVE CONTROL servicing four pumps /central heating, domestic hot water, floor/. Control of one mixing valve; preview and change of parameters of the main ONLINE controller - extra payable option;
Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler.
automatyczne czyszczenie wymiennika Mechanical heat exchanger cleaning system;
ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger;

Ceramic catalysts stabilising combustion process;
Fuel self-ignition system;
Central pellet burner with automatic cleaning function as a standard;
zamiana strony zasobnika
Possibility of moving the fuel tank;
kompaktowe_wymiary.jpg Compact dimensions;

Specification / boiler type

unit 10 15 20 25 30 40
Power range kW 3,0-10 4,5-15 6,0-20 7,5-25 9,0-30 12,5-40
Heating area

m2

1,3 1,5 1,9 2,3 3,0 4,2

Area of heated rooms 1

m2

to 125 to 185 to 250 to 310 to 375 to 500

Capacity of fuel container 2

kg ~114 ~146 ~146 ~146 ~189 ~228
Optimum thermal efficiency % 94,2 92,3 92,2 91,7 91,7 92,0

Energy efficiency class

  A+ A+ A+ A+ A+ A+

Max. permissible work pressure

bar 1,5
Required flue gas draught mbar 0,12 0,15 0,18 0,18 0,20 0,25

Water temperature on supply max.

°C 65/80

Boiler weight 3

kg ~355 ~375 ~411 ~448 ~543 ~645
Boiler water tank capacity l 77 96 103 111 128 168
Chimney section cmxcm 14x14 14x14 16x16 16x16 18x18 20x20
Chimney section

Ø mm

160 160 180 180 200 220

Minimum chimney height 

m

5

5

5

6

6

7

Supply and return socket diameter

cal

1 ½ ’’ 

Release socket diameter

cal

½ ’’

Diameter of the exhaust gas socket

mm 159 159 178 178 178 178

 

1 Maximum area of heated rooms estimated for unit heat demand q=80 W/m2.

2 Fuel tank capacity for pellet bulk density 0,65 kg/dm3.

3 Boiler weight depends on its additional equipment.

 

Height of boiler can be additionally adjusted by means of provided levelling legs. The regulation of legs varies from 38 to 50 mm.