Boilers with feeder biomass

Calori

Zobacz produkt w 360°

 

 

gwarancja_5_lat.jpg 5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;
stal.jpg Heat exchanger made of certified high-grade steel;
sprawnosc 94 High thermal efficiency reaching 92,9 - 94,3% due to increased heat recovery from flue gases;
sterownik_APC_K_slim.jpg APC K SLIM ADAPTIVE CONTROL servicing three pumps /central heating, domestic hot water, floor/. Control of one mixing valve; preview and change of parameters of the main ONLINE controller - extra payable option;
NZ Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler;
adaptive_control ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger;
zawirowacze
Swirlers system increasing heat recovery from generated power;
automatyczny_zaplon Fuel self-ignition system;
 palnik_pelletowy_centralny Pellet burner with automatic cleaning function in standard;
kompaktowe_wymiary
Compact dimensions;

Specification / boiler type

unit 11 15 20 24 30

Fuel

- wood pellet with diameter 6 mm

Power range

kW 3,3-11,6 4,3-14,6 5,7-20,5 6,9-24,9 8,4-29,5

Heating area

m2

1,4 1,8 2,3 2,6 2,9

Area of heated rooms 1

m2

to 135 to 185 to 250 to 310 to 375

Capacity of fuel container 2

kg ~90 ~104 ~118 ~124 ~142

Optimum thermal efficiency

% 92,9 93,2 93,2 94,3 93,3

Energy efficiency class

- A+ A+ A+ A+ A+

Max. permissible work pressure

bar 3,0

Required flue gas draught

mbar 0,14 0,17 0,20 0,23 0,26
Water temperature on supply max. °C 65/80

Boiler weight 3

kg 237 261 307 331 364

Boiler water tank capacity

l 50 60 75 86 95

Chimney section

cmxcm 14x14 14x14 14x14 16x16 18x18

Chimney section

Ø mm

160 160 160 180 200

Minimum chimney height

m

5

5

6

6

6

Supply and return socket diameter

cal

GZ 1 ¼’’ / GW 1 ¼’’

Diameter of the exhaust gas socket

mm 159 159 159 159 159

Supply

V/Hz

~230/50

 

1 Maximum area of heated rooms estimated for unit heat demand q=80 W/m2.

2 Fuel tank capacity for pellet bulk density 0,6 kg/dm3.

3 Boiler weight depends on its additional equipment.

 

Height of boiler can be additionally adjusted by means of provided levelling legs. The regulation of legs varies from 38 to 50 mm.

Additional equipment components shall be added during ordering of the boiler because there is no possibility of installation in the future.

Visitors counter: 6758129 , today: 93 , yesterday: 104 , online: 0