Charging Boilers
KDR 3 A

DESCRIPTION
KDR 3 boilers are adapted for combustion of solid fuels, especially wood in form of chunks, and large combustion chamber allows several-hour operation of the equipment. Boilers are operating using natural draught and combustion process does not require use of electric energy. Amount of air necessary for combustion process is adjusted using lifting flap in ash-pan doors, which can be adjusted manually or using string of draught controller /additional equipment/. Boilers are factory adapted for installation of blowing set. Heat exchanger of boilers is made of certified boiler steel of thickness 6mm and insulated with mineral wool to limit heat losses.
![]() |
4 years of warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler |
![]() |
Heat exchanger made of certified high-grade boiler steel; |
![]() |
high thermal efficiency reaching 82,2-83% thanks to increase heat recovery from flue gases |
![]() |
in version for closed system as KDR 2 NZ* |
![]() |
combustion process adjustment using draught regulator* or knob in ash-pan doors |
![]() |
Large combustion chamber |
![]() |
wide range or power |
![]() |
factory adapted for installation of blowing set |
![]() |
adjustment of secondary air inflow |
(*) - extra payable equipment, installed on Customer’s request
Name of the boiler | KDR 3 A |
||||||||
Specification/boiler type | Unit | 12 | 15 | 20 | 25 | 30 | 35 | 40 | 50 |
Power range | kW | 3,6-12 | 4,5-15 | 6,0-20 | 7,5-25 | 9,0-30 | 10,5-35 | 12,0-40 | 15,0-50 |
Heating area |
m2 |
1,4 | 1,8 | 2,2 | 2,4 | 2,7 | 3,2 | 3,6 | 4,3 |
Area of heated rooms 1 |
m2 |
to 150 | to 200 | to 220 | to 250 | to 300 | to 350 | to 400 | to 500 |
Single fuel charging | kg | ~23 | ~30 | ~39 | ~45 | ~73 | ~106 | ~106 | ~152 |
Optimum thermal efficiency | % | ~82,2-83,0 | |||||||
Energy efficiency class | - | D | D | D | D | D | D | D | D |
Max. permissible operation pressure |
bar | 1,5 | |||||||
Required flue gas draught | Pa | 23 | 25 | 27 | 28 | 30 | 31 | 32 | 34 |
Max. temp. of water on supply | °C | 65/90 | |||||||
Boiler weight 2 |
kg | 243 | 299 | 336 | 364 | 404 | 476 | 511 | 589 |
Boiler water tank capacity | l | 62 | 82 | 106 | 115 | 127 | 146 | 151 | 185 |
Chimney section | cmxcm | 14x14 | 14x14 | 14x14 | 16x16 | 17x17 | 18x18 | 19x19 | 21x21 |
Chimney section |
Ø mm |
160 | 160 | 160 | 170 | 190 | 200 | 210 | 230 |
Minimum chimney height |
m |
6 |
6 |
7 |
8 |
8 |
8 |
9 |
9 |
Width | mm | 547 | 597 | 597 | 647 | 647 | 747 | 747 | 797 |
Depth |
mm |
905 |
963 |
1080 |
1080 |
1088 |
1088 |
1088 |
1088 |
Height | mm | 1284 | 1350 | 1350 | 1350 | 1550 | 1550 | 1650 | 1800 |
Diameter of supply and return Dn |
mm |
G1 ½” |
|||||||
Diameter of flue | mm | 159 | 159 | 159 | 178 | 178 | 178 | 194 | 244 |
Height to bottom edge of the flue |
mm |
983 |
1033 |
1033 |
1014 |
1214 |
1214 |
1303 |
1405 |
Dimensions of charging chamber and charging hole |
width depth height width x height |
258 380 230 258x188 |
308 430 230 308x238 |
308 547 230 308x238 |
358 547 230 358x238 |
358 547 371 358x288 |
458 547 424 458x288 |
458 547 424 458x288 |
508 547 547 508x288 |
1 Maximum area of heated rooms estimated for unit heat demand q=80W/m².
2 Boiler weight depends on the equipment.
3 Extra paid option, installed on the customer’s request.
4 Draught controller is not equipment of the boiler.