Charging Boilers
Delta

DESCRIPTION
DELTA boilers are intended for combustion of hard coal and firewood. Combustion process is mechanically controlled using knob of lifting flap in ash-pan doors. Moreover, adjustable flap for adjustment of inflow of secondary air is located in charging doors. This solution significantly improves course of combustion process and parameters of flue gas emission. To also possible to adjust combustion process using draught regulator. Furthermore, boilers are factory adapted for assembly of fan and electronic controller. The advantage of the boiler is capacious combustion chamber ensuring many hours of equipment operation and large charging doors facilitating charging of fuel.
![]() |
4 years of warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler. |
![]() |
Heat exchanger made of certified high-grade boiler steel; |
![]() |
high thermal efficiency reaching 83% thanks to increase heat recovery from flue gases
|
![]() |
adapted for installation in closed circuit in version NZ* |
![]() |
mechanical movable grate for removal of ash from water grates
|
![]() |
large furnace chamber |
![]() |
adjustment of secondary air inflow |
![]() |
combustion process adjustment using draught regulator* or knob in ash-pan doors |
![]() |
factory adapted for installation of blowing set |
(*) - extra payable equipment, installed on Customer’s request
Power range: 8-22 kW - Table no. 1
Power range: 25-49 kW - Table no. 2
Name of the boiler | Delta | ||||||||||
Specification/boiler type | Unit | 8 | 12 | 16 | 19 | 22 | 25 | 28 | 35 | 42 | 49 |
Power range | kW |
2,4 -8 |
3,6 - 12 |
4,8 -16 |
5,7 -19 |
6,6 -22 |
7,5 -25 |
8,4- 28 |
10,5 -35 |
12,6 -42 |
14,7 -49 |
Heating area |
m2 |
1,2 | 1,4 | 1,8 | 2,0 | 2,2 | 2,4 | 2,7 | 3,2 | 4,2 | 4,9 |
Area of heated rooms 1 |
m2 |
to 110 | to 140 | to 180 | to 200 | to 230 | to 250 | to 280 | to 350 | to 440 | to 500 |
Single fuel charging | kg | ~13 | ~18 | ~23 | ~23 | ~28 | ~32 | ~37 | ~51 | ~56 | ~61 |
Optimum thermal efficiency | % |
80,7-82 % |
|||||||||
Energy efficiency class | - | D |
D |
C | C |
D |
D |
D |
D |
D |
D |
Max. permissible operation pressure |
bar | opened system 1,5 / closed system 2,5 | |||||||||
Required flue gas draught | Pa | 18 | 21 | 24 | 26 | 27 | 28 | 29 | 31 | 32 | 34 |
Max. temp. of water on supply | °C | 65/90 | |||||||||
Boiler weight 2 |
kg | 231 | 258 | 289 | 302 | 325 | 354 | 382 | 429 | 489 | 555 |
Boiler water tank capacity | l | 49 | 55 | 70 | 74 | 82 | 90 | 98 | 114 | 136 | 158 |
Chimney section | cmxcm | 14x14 | 14x14 | 14x14 | 14x14 | 15x15 | 16x16 | 16x16 | 18x18 | 20x20 | 21x21 |
Chimney section |
Ø mm |
160 | 160 | 160 | 160 | 165 | 175 | 185 | 200 | 220 | 235 |
Minimum chimney height |
m |
5 |
5 |
6 |
6,5 |
7 |
7 |
7,5 |
8 |
8 |
8,5 |
Width | mm | 646 | 646 | 646 | 646 | 696 | 746 | 796 | 846 | 846 | 846 |
Depth |
mm |
990 |
1082 |
1094 |
1094 |
1094 |
1094 |
1094 |
1114 |
1262 |
1410 |
Height | mm | 975 | 975 | 1075 | 1125 | 1125 | 1125 | 1125 | 1175 | 1178 | 1180 |
Diameter of supply and return Dn |
mm |
G1 ½” |
|||||||||
Diameter of flue | mm | 159 | 159 | 159 | 159 | 159 | 159 | 178 | 178 | 178 | 178 |
Height to bottom edge of the flue |
mm |
573 |
573 |
673 |
723 |
723 |
723 |
714 |
765 |
768 |
768 |
Dimensions of charging chamber and charging hole |
width depth height width x height |
258 270 240 258x208 |
258 365 240 258x208 |
258 404 280 258x238 |
258 404 280 258x288 |
308 404 280 308x288 |
358 404 280 358x288 |
408 404 280 408x288 |
458 424 330 458x288 |
458 464 330 458x288 |
458 504 330 458x288 |
1 Maximum area of heated rooms estimated for unit heat demand q=95W/m².
2 Boiler weight depends on the equipment.
3 Extra paid option, installed on the customer’s request.
4 Foot of mobile grate is not available for 8kW model.
5 Draught controller is not equipment of the boiler.